Contract No.:CH-2/RC-18019002/112003/AC/STEAM STERILIZERS /4/
/CCOAD |
Dated :
25.03.2004. |
To
|
M/s.
STEELS, No.R-593, New
Rajinder Nagar, NEW DELHI-110
060. |
BY REGD. POST
A.D. | |
|
Subject: |
Rate Contract for
supply of AUTO CLAVE STEAM STERILIZERS valid From 25.03.2004
31.03.2005. | |
|
Reference: |
(i) This office
tender enquiry no.CH-2/RC-18019002/112003/ AC/Steam Sterilizers opened on
30.12.2003. (ii) Your quotation
No. Nil dated Nil subsequent letters dated 28.01.2004 &
20.02.2004. | |
Dear
Sirs,
You are hereby informed that your above referred tender read with
subsequent letters mentioned above for the stores specified in the Schedules
annexed has been accepted. This Rate Contract will be governed by the terms and
conditions brought out in the form no. DGS&D-1001. The Rate Contract and the
Schedules annexed hereto shall be the sole repository of this Rate
Contract/Transaction.
Schedules
annexed:
Yours
faithfully,
(G.M.RAO)
ASST
DIRECTOR(SUPPLIES)
For and on behalf of the
Purchaser(s) named in the form DGS&D – 1001
-- 2
--
Copy
to:
1.
The Chief Controller of
Accounts, Department of Commerce (Supply Division),
(Through
Authentication).
2.
Directorate General of
Supplies & Disposals,
3.
Deputy Director General of
Supplies & Disposals, Kolkata.
4.
Deputy Director General of
Supplies & Disposals, Mumbai.
5.
Deputy Director General
(QA), Chennai.
6.
Deputy Director General
(QA), Kolkata.
7.
Deputy Director General
(QA), Mumbai.
8.
Deputy Director General
(QA), DGS&D,
9.
Inspection Authority :
A.D.G.(Q.A.), DGS&D.,
10. Quality Assurance Officer :
Director (Q.A.),D.G.S.& D., Jeevan Tara Bldg., Sansad
Marg,
New
Delhi-110 001.
11. Concurrent
Audit
12. MIS
Cell
13. Ledger
Clerk
14. Computer
Section.
15. All Direct Demanding
Officers as per mailing list maintained.
16. Deputy Director of
Supplies.
17. CDN
section.
18. Master
Folder.
-- 3 --
|
SCHEDULE
‘A’ |
|
| |||||||
|
|
|
| |||||||
|
1 |
Rate Contract
No.:CH-2/RC-18019002/112003/AC/STEAM STERILIZERS /4/
/CCOAD
Dated 25.03.2004 for
supply of AC STEAM STERILIZERS. |
|
| ||||||
|
2 |
Advance Rate Contract
No. NIL Dated Nil. |
|
| ||||||
|
3 |
a) |
Name and full address
of the firm: |
M/s.
STEELS, No.R-593, New
Rajinder Nagar, NEW DELHI-110
060. |
|
| ||||
|
|
|
||||||||
|
|
|
||||||||
|
|
Telephone
No.: |
+91-11-55457722,
25767191 |
|
| |||||
|
Telex
No.: |
-- |
|
| ||||||
|
Fax
No.: |
-- |
|
| ||||||
|
E-mail
address: |
-- |
|
| ||||||
|
b) |
Name and address of
manufacturer: |
Same as
above. |
|
||||||
|
|
|
||||||||
|
|
Telephone
No.: |
Same as above
|
|
| |||||
|
Telex
No.: |
-- |
|
| ||||||
|
Fax
No.: |
-- |
|
| ||||||
|
4 |
Validity of Rate
Contract: |
From 25.03.2004 to
31.03.2005. |
|
| |||||
|
5 |
Description of item,
specification, unit rate, etc. |
|
| ||||||
|
Sl. No. |
Item
No. |
Description of item
& Specification |
Unit |
Rate per
unit |
| ||||
|
(1) |
(2) |
(3) |
(4) |
(5) |
| ||||
|
| |||||||||
|
1. |
II(a) |
Horizontal
Cylindrical Steam Sterilizers Pressure Type
for Hospital and Pharmaceutical use : Pressure type steam
sterilizers of horizontal cylindrical type designed for the working
pressure of 126 KN/m2 (1.26
Kg/cm2 approx.) but set to operate at 105 (+) 15 KN/m2
(1.05 + 0.15 Kg/cm2 approx.) and the temperature inside is about 121’C
with built in steam generator which shall be electrically heated by
immersion heaters having
mineral filled sheathed heating elements conforming to IS:4159/2002 duly
ISI marked and complying with safety requirements as per IS: 302-2-201
(1992). The immersion heaters
shall be wired for operation in 3 Phase, 4 Wire 400/440 Volts, 50Hz, A/C
supply. The horizontal
cylindrical steam sterilizer shall conform to IS:3829(Part 1)/ 1999 with
provision of silicon door gasket (expansion type) for the sterilizers and
of the following sizes and
with corresponding electric loads :
|
|
| ||||||||||||||||
|
No. |
1,23,000/- | |||||||||||||||||||
|
No. |
1,23,000/- | |||||||||||||||||||
|
No. |
1,31,000/- | |||||||||||||||||||
|
|
|
-- 4
--
|
2. |
III (a)
|
Horizontal
Rectangular type / Same as II(a) above
but of Horizontal Square or Horizontal Rectangular type in the following sizes and with
corresponding electrical load and conforming to IS:3829 (Part 1) /
1999.
|
|
| ||||||||||||||||||
|
No. |
3,15,000/- | |||||||||||||||||||||
|
No. |
4,15,000/- | |||||||||||||||||||||
|
|
| |||||||||||||||||||||
|
3. |
IV. |
Vertical Cylindrical
type Steam Sterilizers Pressure type Pressure type steam
sterilizers of Vertical Cylindrical type designed for working pressure of 126 KN/m2 (1.26 Kg/cm2
approx.) but set to operate at 105 KN/m2 + 15KN/m2 (1.05 + 0.15 Kg/cm2
approx.) and saturated steam inside the chamber is minimum 121’C. The Steam generator shall be
electrically heated by
immersion heaters
having mineral filled sheath heating elements conforming to
IS:4159/2002 duly ISI marked and complying with safety requirements as per
IS: 302-2-201
(1992). The immersion heaters
shall be wired for operation on single phase 230 Volts 50 Hz A/C supply or 3 phase 440V 50 Hz A/C
supply as applicable. The
vertical cylindrical type steam sterilizers pressure type shall conform to
IS:3829 (Part 3)/1985 (Reaffirmed 2001) with Amdt. No.1 & 2 with
provision of silicon door gasket (expansion type) for the sterilizers and
of the following sizes with
corresponding electric load :
|
|
| ||||||||||||||||||
|
No. |
43,000/- |
|
(i) |
MATERIAL: The Quality of
Stainless steel as mentioned in governing IS Specification will be used in
the manufacture of above mentioned Sterlizers. |
|
(ii) |
NOTE: YOU SHALL BE FULL RESPONSIBLE FOR
INSTALLATION, COMMISSIONING AND SATISFACTORY DRAWAL FOR AT LEAST 15 CYCLES
OVER A PERIOD OF 3 OR 4 DAYS AT CONSIGNEES
PREMISES. |
-- 5
--
|